CMD SERIES presents cartridge heater a further development of existing conventional type
When working conditions are not very demanding, this series is an alternative to HIGH DENSITY cartridges
HD
MEDIUM DENSITY CARTRIDGE used in mainly
measures in long, do not bear a high load per square centimeter (up to 10 watts)
Diameter (metric & imperial sizes) and Tollerances
|
||||||||||
Ø
|
6,5
|
8
|
10
|
12,5
|
16
|
20
|
1/4"
|
3/8"
|
1/2"
|
5/8"
|
Tollerance
|
-0,03 | -0,04 | -0,04 | -0,05 | -0,05 | -0,06 | -0,03 | -0,04 | -0,05 | -0,05 |
-0,05 | -0,06 | -0,07 | -0,08 | -0,08 | -0,1 | -0,05 | -0,07 | -0,08 | -0,05 | |
Length Tollerance
|
Relative ±1,5% | |||||||||
Absolute ±1mm (minimum) | ||||||||||
Cold insolution Resistance 500 V-DC
|
≥ 10 MΩ | |||||||||
Dielectric Strength
|
1500 V | |||||||||
Maximum leakage current (cold)
|
≤ 0,5 mA | |||||||||
Cold Wattage Tollerance
|
±10% | |||||||||
Maximum Power Density
|
10 W/cm2 | |||||||||
Unheated Zones Length
|
Cables Zone nearly 15 mm | |||||||||
Bottom Disc Zone nearly 15 mm | ||||||||||
Maximum Working Temperature
|
550/600ºC on the external sheath |